Zoll R Series Defibrillator (Recertified)

zoll_r_2ndlife

SIMPLE

  •  Uniform Operating System between the two models
  •  Shares common electrodes, cables, paddles, and batteries
  • Only one therapy cable needed for defibrillation, cardioversion and pacing – no separate 3 lead cable required. The OneStep Complete Resuscitation Electrode has built-in 3 leads in the pad, eliminating extra steps if the patient needs to be paced immediate after resuscitation.

 

SMART

  • Real CPR Help to coach to the proper compression rate and depth during CPR as well as See-Thru CPR to minimize pauses during CPR compressions.
  •  The only defibrillator that recognizes the OneStep Pediatric electrode and automatically lowers the energy setting to 50J to prevent accidental overdose of energy.
  • Unique pediatric algorithms that allow proper analysis of arrhythmias for younger patients.
  •  Optional monitoring capabilities include SP02, EtCO2 and Non-invasive Blood Pressure.
  •  Defibrillator event documentation via internal memory, as well as a removable Compact Flash card for easy data transfer and archiving. Coupled with CodeNet, ZOLL’s unique PDA-based code data management system, the R Series communication capability makes record keeping a breeze. WiFi enabled option available.

 

READY

  •  Conducts an automated self-test once a day. No need to do a 30 J manual test; simply verify the green check mark is present during your shift check.
  •  The reliability you’ve come to count on from ZOLL Medical Corporation, using our proprietary Rectilinear Biphasic high-current waveform.
  •  ZOLL’s patented external pacing offers superior capture at lower mean thresholds, reducing muscle artifact and ensuring more patient comfort and better patient tolerance.

 

External Pacing (Option)

OneStep Pacing: Eliminates the need to connect separate ECG leads

 

Advisory Defibrillation (Option)

Shock Advisory Function: Evaluates ECG rhythm to determine if shock delivery is required.

Protocol Configurations: Configurable for either CPR or shock-first driven protocols. Energy sequences can be configured for single or multiple shocks with fixed or escalating energy levels. The CPR Interval length is configurable in 1 minute increments up to 4 minutes. 

 

Pulse Oximetry with Masimo SET® Technology (Option)

Saturation Range: 1-100% (%SpO2) with a resolution of 1%.

 

End-tidal CO2 (Option)

Transducer Type: CAPNOSTAT 5®: Mainstream.

 

NIBP (Option)

Patient Population: Adult, NeoNate, Pediatric.

Method: Oscillometric.

Control: Automatic and manual measurement.

 

WiFi Capable (Option)

WiFi 802.11b compatibility: WiFi

Compact Flash Card ZOLL P/N: 9214-

0203 or Ambicom WL1100C-CF WiFi

Card.